Pitot Tube Flow Sensors: Multi-Port Insertion Elements for HVAC Duct Networks
Quick Answer: Multi-port averaging pitot tube sensors measure HVAC duct air flow by averaging differential pressure from several impact and static ports. Silver Instruments supplies the SPT-240 insertion series for ducts from DN100 to DN2000, with 4-20 mA HART output, accuracy of plus or minus 1.5 percent of rate, and temperature ratings up to 150 °C. Send your duct size, air velocity, and temperature to get a same-day quote.
HVAC engineers and commissioning teams often skip a simple fact. A single-point pitot tube misses most of the velocity profile in a large supply air duct. Multi-port insertion elements solve that problem. They use several sensing holes across the duct cross section. The result is a stable differential pressure signal that works well for building automation systems.
When Multi-Port Sensors Beat Single Point Devices
In a duct of DN800 or DN1000, air velocity is not uniform. The profile changes after bends, filters, dampers, and fan outlets. A single impact port reads only one spot. A multi-port averaging pitot tube takes the average of 4 to 16 points. That average is closer to the true duct flow. For HVAC networks, the result is fewer false alarms and better energy monitoring.
Most engineers skip this part: straight run matters. We recommend 4 duct diameters upstream and 2 downstream for a multi-port sensor. If you have less straight run, the SPT-240 still works but you should field calibrate the transmitter.
Output Signals and Pressure Ranges
Most HVAC control panels accept 4-20 mA or 0-10 V DC. Silver Instruments offers both. The typical differential range is 0 to 500 Pa for air velocities from 2 to 20 m/s. For high velocity ducts up to 40 m/s, we configure a 0 to 2500 Pa range. The transmitter can be mounted directly on the sensor or remotely. HART protocol is available for loop diagnostics and remote range changes.
Installation in Round and Rectangular Ducts
Installation is straightforward. For round ducts of DN300 to DN1200, the sensor body inserts through a 25 mm or 50 mm weld nipple. For rectangular ducts, the insertion length matches the internal width. You can mount the sensor horizontally or vertically. Most commissioning engineers prefer the horizontal position for liquid condensation drainage. We ship each unit with a compression fitting, identification tag, and a quick start guide.
Field Results from HVAC Projects
Last year, a chiller plant contractor in Vietnam ordered 18 SPT-240 sensors for a pharmaceutical warehouse. Duct sizes ranged from DN600 to DN1400. Air temperature was 12 to 18 °C. The customer required 4-20 mA HART signals to integrate with a Siemens BAS. We calibrated each sensor for a 0 to 800 Pa range. The plant passed commissioning on the first attempt.
In Australia, a hospital HVAC upgrade used our insertion sensors on outside air intakes. The ducts carried 35 °C summer air and condensation was a risk. We supplied 316L stainless steel sensors with PT100 temperature elements built in. That single insertion point delivered air flow and temperature to the building management system.
We have seen this on customer sites many times. A balancing contractor in Manila installed single-point pitot tubes on a DN700 return air duct. The BAS reading jumped every time a VAV box opened or closed. We replaced them with SPT-240 multi-port elements. The signal became stable within one minute.
How to Request a Quote
Send us your duct size (DN or internal width in mm), air velocity range (m/s), operating temperature (°C), and required output signal. We will recommend a model, a differential pressure range, and an insertion length. Contact Silver Instruments at Tel +86-25-68650347, WhatsApp +86-25-52155837, or WeChat +86 15365082610.
Do not send a single-line enquir